Title
Bio-capacitance probe system
Reference number
cb-483-56366637
Solicitation number
26-58103
Publication date
2026-07-29
Tender closing date
2026-08-24T14:00:00
Expected contract start date
2026-09-11
Expected contract end date
2027-11-03
Unspsc description
*Laboratory and scientific equipment
Notice type
Request for Proposal
Procurement method
Competitive - Open bidding
Selection criteria
Lowest Price
Trade agreements
*Canada-Chile Free Trade Agreement (CCFTA)
*Canada-Panama Free Trade Agreement
*Canada-Korea Free Trade Agreement (CKFTA)
*Canada-Honduras Free Trade Agreement
*Canadian Free Trade Agreement (CFTA)
*Canada-Colombia Free Trade Agreement
Regions of opportunity
*Canada
Contracting entity name
National Research Council of Canada (NRC)
Contracting entity address line
1200 Montreal Road
Contracting entity address city
Ottawa
Contracting entity address province
ON
Contracting entity address postal code
K1A 0R6
Contracting entity address country
Canada
Contact info name
Daniel Rusthoven
Contact info email
daniel.rusthoven@nrc-cnrc.gc.ca
Contact info phone
(343) 542-9384
Contact info address line
6100 AVENUE ROYALMOUNT (PORTES 6 & 7)
Contact info city
MONTREAL
Contact info province
Quebec
Contact info postalcode
H4P 2R2
Contact info country
Canada
Attachment
https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/102022/26-58103_npp_en.pdf,https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/102022/26-58103_rfp_en.pdf
Tender description
Acquisition of a new four-probe system enabling real-time measurement of bio-capacitance for cell culture in bioreactors, for up to four bioreactors in parallel. This system will enable real-time estimation of viable cell concentration in those bioreactors.
Measuring bio-capacitance at multiple frequencies, at regular intervals, in order to obtain the capacitance distribution spectrum of the cells, thereby enabling the real-time calculation of other critical cell culture parameters such as cell size, internal cell conductivity, and critical frequency.
The probes to be acquired under this procurement must be compatible with the different types of bioreactors used by the team. In addition, the selected bio-capacitance probes must allow multi-frequency scanning for real-time determination of the intrinsic dielectric properties of the cells through analysis of the ß-dispersion of the signal using the Cole–Cole a model. Finally, the generated data must be capable of being captured in real time both by the control and data acquisition system via OPC-UA communication, and via 4–20 mA communication to enable integration of the probe directly into a control loop.