Tendarix.ca
BUSINESS NEWS
Storm Clouds Continue to Gather Over Canada’s Economy· EnergyNowOpinion: Mark Carney’s climate ambitions still threaten Canada’s economy· Financial PostQ3-26 Canadian Business Outlook Survey: More firms plan cost pass-through· RBCA new chapter in Canada-India economic relations· Business Council of CanadaStaying in Canada is a 'huge relief' for Alberta business leaders· CBCTrump administration cancels some Canada tariffs amid close midterm races· NBC NewsWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaCarney, Erdogan launch ‘strong and resilient’ Canada-Turkiye partnership· Al JazeeraGlobal trade is changing how the Canadian economy works· Bank of CanadaEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsSoft economy should limit Bank of Canada's rate hikes: Capital Economics· BNN BloombergCanada’s services PMI shows sector shrinking for fourth straight month in September· The Globe and MailCanada’s $1 Trillion Defence Buildout Could Strengthen Canadian Industry· Canadian Chamber of CommerceCanada’s inflation data, business survey on tap ahead of BoC decision· RBCPosthaste: U.S. businesses feel fresh pain from trade war with Canada, says this hot take on the economy· Financial Post
← All tenders
Public Works and Government Services Canada

analyseurs par injection en flux

Advance Contract Award Notice (ACAN)
Estimated value
Not disclosed
Deadline
January 6, 2021
Published
December 18, 2020
Type
Goods
Explore similarLaboratory and Measuring and Observing and Testing EquipmentQuebec

Full description

Trade Agreement: CFTA / FTAs with Peru / Colombia / Panama / Korea
Tendering Procedures: Generally only one firm has been invited to bid
Non-Competitive Procurement Strategy: Exclusive Rights
Comprehensive Land Claim Agreement: No
Vendor Name and Address:
ATS Scientific Inc.
4030 MAINWAY
BURLINGTON Ontario
Canada
L7M4B9
Nature of Requirements:

Flow Injection Analyzer

K3D56-210429/A
Pan, Long
Telephone No. - (416) 262-0724

1. Advance Contract Award Notice (ACAN)

An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.

2. Definition of the requirement

Environment and Climate Change Canada (ECCC) intends on entering into a Contract with ATS Scientific Inc., Ontario for the provision of two dual channel flow injection instrument, one ammonia and one with total nitrogen modules.

Background:
The Canadian Air and Precipitation Monitoring Network (CAPMoN) is designed to study the regional patterns and trends of atmospheric pollutants such as acid rain, smog, particulate matter and mercury, in both air and precipitation. CAPMoN contributes to the department's Core Responsibility of Preventing and Managing Pollution.

Objective:

This Contract is intended to support the Canadian Air and Precipitation Monitoring Network (CAPMoN) analysis of trace level inorganic air and precipitation samples in various media. The systems requested are to support the Canadian Air and Precipitation Monitoring Networks 35+ years of data, produced by analyzing the chemistry of air and precipitation samples. There are two Flow Injection Analyzers used for analysis of nitrogen in precipitation samples. These instruments are run continuously throughout the year (2 days per week). The current systems have reached the end of their lifetime.

Scope of Work:

Two new fully automated, high throughput, dual channel, flow injection analyzers (FIA) that use EPA methods 350.1 and 351.2, in accordance with the specifications detailed and consists of the following:

1. 2 Auto-samplers
2. 2 Reagent pumps
3. 2 dual channel complete sample processing modules and unit, one for ammonium and one for total nitrogen, utilizing array spectrometer
4. Inline digestion system for total nitrogen module
5. Software
6. Documentation
7. Warranty
8. Installation and Training

3. Criteria for assessment of the Statement of Capabilities (Minimum Essential Requirements):

The Dual Channel Flow Injection Analyzer system must provide:
1) A dual analytical colourimetry system capable of measuring two separate sample streams for the analysis of ammonium and total nitrogen.
2) The system must be modular so that ammonium and total nitrogen systems may be analyzed simultaneously or independently of each other. A full view of fluid movement in manifold is required.
3) Control and data handling capabilities via software that is compatible with Windows 10. Must have to ability in the software to analyze samples while running with different variable analysis on the fly.
4) Application flexibility to allow for alternative analytical modules to be applied in the future;
5) Configuration options for future upgrades and improvements including consumables and hardware.
6) Method Detection Limits less than or equal to:
Ammonium: 0.005ppm
Total Nitrogen: 0.020ppm.
Analytical specifications:
The minimum system performance specifications listed below are intended to ensure that the system supplied is able to meet the performance level required.

a) Facilities

The FIA must be able to operate under the following conditions: Temperature: 15-30°C. (max. rate of change 5°C /hr.). Humidity (non-condensing): 20-80%. Voltage: 120V, 60Hz.

b) Autosampler

A random access XYZ autosampler must be provided. The sample probe must be metal-free and continuously rinsed by fresh wash solution by an integral rinse pump when not in use.

Sampler racks must be able to accommodate generic 17 X 100mm tubes. Analysis trays must be able to accommodate no less than 120 samples.

c) Reagent pump

A peristaltic pump capable of delivery of greater than or equal to 5 different reagents is required. The pump must use colour coded, flow rated tubing.

d) Sample Processing Modules

The sample introduction system must use a sample loop to accurately measure the sample volume introduced into the reagent stream. The sample introduction system must use Flow Injection Analysis (FIA) technology and provide a high throughput of samples analysis.

Sample introduction must allow for the simultaneous injection of sample into parallel reagent streams using FIA methodology.

The reagent manifolds must accommodate total nitrogen and ammonium methods in parallel suitable for simultaneous analysis.

A heating block is required to accelerate the ammonium reaction.

The manifold must be able to house a cadmium column for reduction of nitrate to nitrite. The vendor must be able to provide cadmium columns for total nitrogen methodology. The columns must have a guarantee of quality.

e) System Unit

Two dual channel core system units are required.
Ammonium and total nitrogen will be analyzed in two duplicate parallel systems to maximize throughput.
The systems must provide high throughput of analysis with multiple modules running in parallel
The system units must supply a full absorbance spectrum source to in real time.
The units manifolds must allow for full view of fluid movement.
The system unit must manage the electronic signals to and from multiple sample modules running in parallel.
The system unit is the power source for all modules.

f) Inline digestion system for total nitrogen

An inline digestion preparation system is required. The system must provide a heating block and an ultra violet light source.

g) Documentation:
The system must be supplied with full documentation including an operator's manual, administration and maintenance manual, spare parts catalog and a comprehensive applications handbook specifically written for the system being offered.

Standard Operating Procedures (SOPs) must be provided in both written as well as electronic format.

h) System Implementation:

A minimum one-year parts and labour warranty that provides both on-site as well as phone support must be included as standard. This warranty must include the full instrument and parts. A qualified service tech must reply by phone within 24 hours of a call to the vendor; and/or an on-site repair/replacement of components within a 48-hour period 5 days a week.

An additional minimum one year of phone support must be included.

Trained application consultants must be available to discuss customized applications support. The application consultant must be capable of on-site visits at the vendor’s expense for a period of one year. The one year period shall commence on the day of instrument acceptance. Application consultants will be available for contact by phone for a minimum of 10 years.

4. Applicability of the trade agreement(s) to the procurement
This procurement is subject to the following trade agreements:
Canadian Free Trade Agreement (CFTA);
Canada - Chile Free Trade Agreement (CCFTA);
Canada - Colombia Free Trade Agreement;
Canada - Honduras Free Trade Agreement;
Canada - Korea Free Trade Agreement;
Canada - Panama Free Trade Agreement;
Canada - Peru Free Trade Agreement (CPFTA).

5. Justification for the Pre-Identified Supplier

The FIALab flow injection analyser is the replacement for the current Lachat system in use. The FIALab flow injection proposed by ATS Scientific Inc. is the direct replacement for the outdated Lachat model, which are no longer manufactured nor supported in the future. The only authorized seller of this specialized equipment required by the network in Canada is ATS Scientific Inc. ATS Scientific Inc. has exclusive rights to distribute the FIALab instruments requested in Canada. The 350.1 EPA methodology that these instruments use, are essential to attain the detection limits required in CAPMoN and the continuous analysis of thousands of samples annually. All flow injection instruments currently in-use in the laboratory were provided by ATS Scientific Inc. and the parts and consumables from current- in use instruments are compatible with the flow injection analyzer proposed. The FIALab methodology provides the rapid chemistry to complete thousands samples, follows the US EPA 350.1 methods already established and is compatible with pump, autosampler and consumables already established. This is essential for maintaining the integrity of CAPMoN’s long term monitoring data.

6. Government Contracts Regulations Exception(s)

The following exception(s) to the Government Contracts Regulations is (are) invoked for this procurement under subsection 6(d) only one person is capable of performing the contract.

7. Exclusions and/or Limited Tendering Reasons

The following exclusion(s) and/or limited tendering reasons are invoked under the (section of the trade agreement(s) specified):

  • Canadian Free Trade Agreement (CFTA) / Article 513.1(b) (iii)
  • Canada-Chile Free Trade Agreement (CCFTA) / Article Kbis-09, para 1 (b)
  • Canada-Colombia Free Trade Agreement / Article 1409 para 1 (b) (iii)
  • Canada-Honduras Free Trade Agreement / Article 17.11 para 2 (b) (iii)
  • Canada-Korea Free Trade Agreement / which defers to WTO-AGP Article XIII, para 1 (b) (iii)
  • Canada-Panama Free Trade Agreement / Article 16.10 para 1 (b) (iii)

8. Period of the proposed contract or Delivery date
The products must be delivered by March 31 2021.

9. Cost estimate of the proposed contract

The estimate value of the contract is $174,370 CAD, applicable taxes extra.

10. Name and address of the pre-identified supplier

ATS Scientific Inc.
4030 Mainway,
Burlington ON
Canada
L7M 4B9

11. Suppliers' right to submit a statement of capabilities

Suppliers who consider themselves fully qualified and available to provide the goods, services or construction services described in the ACAN may submit a statement of capabilities in writing to the contact person identified in this notice on or before the closing date of this notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.

12. Inquiries and submission of statements of capabilities

Inquiries and statements of capabilities are to be directed to:

Name: Long Pan
Title: Supply Team Leader, Procurement Directorate
Organization: Public Services and Procurement Canada - Ontario Region
Email: l•••••••@••••••••.••.ca
Tel: 416-262-0724

Delivery Date: Above-mentioned

You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.

An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.

Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.

The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Intended sole-source award

The buyer plans to award this contract to a named supplier without competition. If your business can do this work, send a statement of capabilities to the contracting authority before January 6, 2021. If it qualifies, the buyer must open a full competition.

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
PW-_TOR-018-8004
Solicitation no.
K3D56-210429/A
Buyer
Public Works and Government Services Canada
Notice type
Advance Contract Award Notice
Method
Non-competitive
Procurement category
*GD
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

GSIN
*N6640 — *Laboratory Equipment and Supplies
UNSPSC
UNSPSC 41000000 — Laboratory and Measuring and Observing and Testing Equipment

Delivery & regions

Province
Quebec
Regions of delivery
*Ontario (except NCR)

Key dates

Published
December 18, 2020
Closes
January 6, 2021
Amendment no.
000

Contact

End-user
Environment Canada
Sign up free to see the contact details

Award history

10 past awards in this classification and 5 likely incumbents from this buyer. Pro shows who won and for how much.

Upgrade to Pro

Live tenders

National Research Council of Canada (NRC)3 days left

Question/Answer #2 RFP 26-58124 Remotely Piloted Aircraft System (RPAS)-Deployable Integrated Topographic and Bathymetric (Topo-Bathymetric) LiDAR System

Goods
80 MATCHView →
National Research Council of Canada (NRC)3 days left

NPP 26-58124 Remotely Piloted Aircraft System (RPAS)-Deployable Integrated Topographic and Bathymetric (Topo-Bathymetric) LiDAR System

Indigenous set-asideGoods
79 MATCHView →
National Research Council of Canada (NRC)5 days left

Purchase of eleven (11) Electrometer/High-Resistance Meters and Accessories (Keithley 6517B or Equivalent)

Goods
80 MATCHView →