Tendarix.ca
BUSINESS NEWS
Storm Clouds Continue to Gather Over Canada’s Economy· EnergyNowCanadian economy lost 68,000 jobs in September, marking second straight month of surprise declines· CBCBusiness groups warn of irreversible economic consequences if trade deal remains in limbo· Financial PostWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaGlobal trade is changing how the Canadian economy works· Bank of CanadaHoles In Value Chains Are Holding Back Five Sectors That Have The Potential To Reshape Canada’s Economy For The Better· Canadian Chamber of CommerceEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsRegina business leaders to hear outlook on Canada's economy· SaskToday.caTiff Macklem on tariffs, inflation and Canada’s economic crossroads· PNI Atlantic NewsFive bold swings to advance the Canadian economy· Be GiantCanadian Business Leadership Takes Centre Stage in Calgary· Canadian Chamber of CommerceDeloitte expects slowing pace of economic activity in Canada into 2027· Financial PostAtlantic business leaders call for regional policies and more natural resource development· CBCWhat would being an 'associate member' of the EU mean for the Canadian economy and businesses?· Financial PostBank of Canada rate hikes to be limited by soft economy, report says· The Globe and Mail
← All tenders
National Research Council Canada

ensemble de pièces de rechange pour le laser à colorant Precision Scan existant

Other
Estimated value
Not disclosed
Deadline
November 8, 2023
Published
October 24, 2023
Type
Goods
Explore similarLaboratory and Measuring and Observing and Testing EquipmentOntario
Awarded
This contract has been awarded. Details are drawn from the federal award notice for this solicitation.
Winning supplier
SIRAH LASERTECHNIK GMBH
Contract value
CAD $101.3K
Award date
2023-12-13
Supplier location
Grevenbroich, Rhein-Kreis Neuss
Advance Contract Award Notice

Full description

1. Advance Contract Award Notice (ACAN):
An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.
2. Definition of the Requirement:
The National Research Council’s Aerospace Research Centre's gas turbine facilities has a requirement for the supply and delivery of (one) Sirah Precision Scan dye laser, (one) Quanta Ray Nd: YAG Laser, (one) LG-LIFT-30 grating, (one) THU-205-N third harmonic generator, (one) wavelength separation unit, and one set of replacement parts. These requirements are for optical diagnostic equipment for studying gas turbine combustion systems such as fuel injectors and sprays, combustors and burners, and compressor and turbine passages. This equipment will be used to maintain and expand NRC’s intellectual property conducted through research for industry clients, research partners and academia.

This requirement is for an additional delivery of an identical system from the manufacture of NRC’s existing Sirah Precision Scan Dye Laser and software. The equipment is fully compatible meaning no alterations between the proposed equipment and the existing equipment are required. Both pieces of equipment operate on a single software platform manufactured by Sirah Precision Scan.

3. Any interested supplier must demonstrate by way of a statement of capabilities that its product/equipment/system (as appropriate) meets the following requirements:

(a) Sirah Precision Scan dye laser:

  • Resonator Gratings ruling plane must be vertically mounted to protect against dust build up and stray beams. The resonator is mounted horizontal therefore. The dye laser must be pumped with the right polarization to obtain good conversion. (polarization optimized)
  • Resonator must be mounted on thermally stable stainless-steel plate and mounted independently of the laser housing. It decouples the resonator from mechanical stress of the laser housing and allows easy and quick resonator exchange. Calibration and configuration parameters must be stored on the driving electronics of the resonator assembly. Connecting the resonator electronics to the laser system must be detected automatically by the system
  • Resonator must have the possibility to change the grating in grazing position without re-adjustment. An automated grating exchange mechanism (grating lift option) so that gratings with different groove densities can be used. This option allows for gap free tuning with high efficiency over a large tuning range
  • Between resonator and preamplification there must be an ASE-cleaning optics to improve polarization and reducing ASE. These optics have to be designed for high power and the complete tuning range of the dye
  • Resonator must feature precision sine-bar driven with high resolution direct drive stepper motor, no pulleys or gears, to eliminate backlash
  • Resonator and system scan control software to be free and open source with updates readily available on the web
  • System must have LabView® drivers / VI’s for control of dye laser system operation. A programmer’s guide must be provided
  • System must incorporate interchangeable dye cells for simple and rapid dye exchange. System re-alignment shall not be needed after cell exchange. Exchange off cells must be tool free. Change of amplifier and resonator cells to take no longer than 2 minutes
  • Dye laser must come with a touch-panel remote control to allow for stand-alone operation without additional computer
  • Dye circulator must be quiet, compatible with non polar solvents (like Dioxan), and be capable of 1-100 Hz operation. For safety reasons, circulator must feature an illuminated main switch which indicates operation
  • All critical manual dye laser adjusters must be top accessible to allow for adjustment from either side of the laser. The lid of the laser can be mounted on both sides of the laser housing so that the laser can be operated from both sides after flipping the lid
  • Optional integrated frequency doubler must have Look-Up-Table and auto tracker option for scanning
  • Dye laser should have modular options for non linear processes to cover 190 nm to 13 µm
  • Modular system: each dye laser in the field can be upgraded or modified with exchangeable modules for resonator, amplifiers and frequency conversion units. Installed modules (except for the amplifiers) are automatically detected by the electronic system and the control software
  • Easy switching of pump optics to allow quick change of pump laser wavelength. Double-Wavelength-Option
  • Free (travel and accommodation excluded) factory trainings provided by the manufacturer

(b) Quanta Ray Nd: YAG Laser:

  • The laser has dual-rod oscillators with two amplifier stages, enabling output energies up to 2.5 J per pulse at 1064 nm
  • The laser should stabilize any thermal imbalance in the Nd:YAG gain medium eliminating fluctuations in output beam polarization
  • intra-oscillator compensation for thermally-induced birefringence in the Nd:YAG rod, greatly reducing beam depolarization

(c) LG-LIFT-30 grating:

  • The grating should be compatible and interchangeable with the current Sirah Dye laser system (model: PRSC-D-24) in the Gas-turbine laboratory at NRC Aerospace Research Centre
  • The grating lift is compatible with 90 mm and 60 mm gratings, and can be fit into standards pulsed dye laser resonators
  • The grating lift can be detected and controlled by the existing Sirah Control software in the Gas-turbine laboratory at NRC Aerospace Research Centre, and be handheld remotely
  • Absolute wavelength accuracy 98%
  • UV beam diameter 6 mm
  • UV beam divergence:

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
cb-279-81306801
Solicitation no.
23-58150
Buyer
National Research Council Canada
Notice type
Advance Contract Award Notice
Method
Advance contract award notice
Procurement category
*GD
Trade agreements
*Canada-Honduras Free Trade Agreement *Canada-Colombia Free Trade Agreement *Canada-Panama Free Trade Agreement *Canadian Free Trade Agreement (CFTA) *Canada-Chile Free Trade Agreement (CCFTA) *Canada-Korea Free Trade Agreement (CKFTA)
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

UNSPSC
UNSPSC 41000000 — Laboratory and Measuring and Observing and Testing Equipment

Delivery & regions

Province
Ontario
Regions of delivery
*Ottawa
Contract term
November 1, 2023 → ?

Key dates

Published
October 24, 2023
Closes
November 8, 2023
Amendment no.
002

Likely incumbents

(5)

Suppliers who have won similar work from this buyer before.

  1. 1
    Felix Technology Inc.
    3 contracts won· latest March 7, 2025
    CAD $593.6K
    total awarded
  2. 2
    Anton Paar Canada Inc
    3 contracts won· latest May 28, 2025
    CAD $163.5K
    total awarded
  3. 3
    Rollan Tech Inc.
    2 contracts won· latest June 2, 2025
    CAD $316.9K
    total awarded
  4. 4
    Photon Spot
    2 contracts won· latest April 15, 2025
    CAD $188.8K
    total awarded
  5. 5
    Les Solutions Snowhouse 2014 Inc
    2 contracts won· latest April 10, 2024
    CAD $99.3K
    total awarded

Felix Technology Inc. is the most likely incumbent, based on how often and how recently they have won this buyer’s work in this category. To displace them, expect to need a clearly stronger proposition or price.

Live tenders

Department of National Defence (DND)1 day left

Anton Parr SVM 3001 Cold Properties Viscometer and Xsample 340 Sample Changer

Goods
78 MATCHView →
Department of National Defence (DND)1 day left

Anton Parr DMA 5002 Density Meter

Goods
79 MATCHView →
Department of Public Works and Government Services (PSPC)1 day left

PR10192 U6309-244412 Flow Metering Test Bench

Goods
77 MATCHView →