Tendarix.ca
BUSINESS NEWS
Canadian economy lost 68,000 jobs in September, marking second straight month of surprise declines· CBCWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaGlobal trade is changing how the Canadian economy works· Bank of CanadaHoles In Value Chains Are Holding Back Five Sectors That Have The Potential To Reshape Canada’s Economy For The Better· Canadian Chamber of CommerceEastern Canada business leaders call for 'single economy' between Atlantic provinces· CastanetVancouver Cruise Season Pumps Over $1 Billion Into Local Economy as Canada Place Sets Records· Business ExaminerRegina business leaders to hear outlook on Canada's economy· SaskToday.caTiff Macklem on tariffs, inflation and Canada’s economic crossroads· PNI Atlantic NewsDeloitte expects slowing pace of economic activity in Canada into 2027· Financial Post‘We don’t use a stick to attract investments’: Maninder Sidhu on Canada’s global trade push· FirstpostFive bold swings to advance the Canadian economy· Be GiantNavigating uncertainty and adapting to change· Bank of CanadaCanadian Business Leadership Takes Centre Stage in Calgary· Canadian Chamber of CommerceAtlantic business leaders call for regional policies and more natural resource development· CBCBank of Canada rate hikes to be limited by soft economy, report says· The Globe and Mail
← All tenders
Department of Public Works and Government Services (PSPC)

Modular Wind Power for Northern Operations

Request for Proposal (RFP)
Estimated value
Not disclosed
Deadline
October 20, 2026
Published
September 10, 2026
Type
Services
Explore similarPower Generation and Distribution Machinery and AccessoriesQuebec

Full description

This Challenge notice is issued under the Innovation for Defence Excellence and Security (IDEaS) Program Call for Proposals (CFP) Call 006 (W7714-248676/A).

Solicitation Documents reference: See bidding details section.

*For additional general information on the IDEaS Program, visit: https://www.canada.ca/en/department-national-defence/…
_____________
This challenge is open to receive proposals for Component 1a, Component 1b and Component 2. Proposed solutions that fall within technology readiness levels (TRL) 1-9 can be submitted to this challenge.

Steps to apply:
Step 1: read this challenge
Step 2: read the Call for Proposals : See bidding details section
Step 3: propose your solution here : https://defence-innovation-portal.my.site.com/
_____________
Maximum Funding and Performance Period

Multiple contracts could result from this Challenge.

The individual maximum contract funding available under Component 1a (TRL 1-3) is up to $250,000 CAD (excluding applicable taxes) for a maximum performance period of up to 6 months.

The maximum individual contract funding available under Component 1b (TRL 4-5) is up to $1,500,000 CAD (excluding applicable taxes) for a maximum performance period of 12 months.

The maximum individual contract funding available under Component 2 (TRL 6-9) is up to $5,000,000 CAD (excluding applicable taxes). The period of performance will be determined at the time of contract negotiation.

The maximum individual contractual funding and the maximum performance period offered under Component 3 will be determined by Canada at the time of contract negotiation.

This disclosure is made in good faith and does not commit Canada to contract for the total approximate funding.
_____________
Challenge Details

Challenge Title: W7714-248676/016 - Modular Wind Power For North Operations

The Department of National Defence and Canadian Armed Forces (DND/CAF) are seeking innovative solutions to develop modular, stand-alone wind-powered electric generator systems that can be easily transported, deployed, and maintained in remote northern locations to provide reliable, clean energy under extreme cold, high-wind, and icing conditions.

Background & Context

The demand for electrical power and space heating in the Canadian Subarctic and High Arctic is fulfilled almost exclusively with diesel-fired generators. The DND/CAF is seeking to reduce reliance on fossil fuels for the generation of electrical power in the North to minimize operational, logistical, and environmental burdens. Wind turbines suitable for DND/CAF operations are in limited use in the North, as existing installations tend to fall outside the desired capacity range. While small units that deliver up to 6 kilowatts (kW) have been deployed in some communities, and commercial turbines typically exceed 1 megawatt (MW), there is a critical gap in the 25–100 kW range—an ideal scale for remote DND sites. In addition, northern operating conditions present major technical and environmental hurdles that must be overcome before wind turbines can be fully exploited as a source of alternative energy.
Canada's far North and Arctic regions are characterized by seasonally frozen ground, deep snow, rugged terrain, permafrost, and extreme temperatures that can reach –60 degrees Celsius (°C), with frequent high winds of 80–120 kilometers per hour (km/h). Ice rimming of wind turbine blades further threatens performance and efficiency. Innovative approaches are therefore needed to adapt conventional wind-powered electric generator designs to withstand these harsh northern conditions and operate effectively under both low and high wind scenarios. Climate change adds additional complexity, as thawing and refreezing permafrost can cause buildings and foundations to sink, shift, or crack. While not the primary focus of the challenge, consideration must be given to the design of the foundations to keep the turbines level and stable despite seasonal ground movement.

There is a need for wind-powered electricity generators that are logistically efficient, easy to deploy, and maintainable in isolated northern locations. Many DND/CAF sites exist in remote areas or within small Arctic communities that have limited or no road access and must be reached by alternative means of transportation such as barges or heavy-lift aircraft. Consequently, new systems must feature modular designs that can be transported and assembled on site with minimal heavy-lift equipment by non-technicians using commonly available tools. To ensure sustained operation, proposed solutions should use readily available parts, be serviceable by local tradespeople, and operate with minimal human intervention once deployed.

Essential Outcomes

The proposed solution must:

  • Provide a design for a wind-powered electrical generation system in the 25–100 kW range, incorporating details of the structural, mechanical, electrical, and control elements required.
  • Provide integration and operational demonstration plan(s), showing how the wind-powered electric generator system can function in remote northern locations and operate and withstand northern environmental conditions, including extreme cold (down to –60 °C), high winds (up to 120 km/h), and icing conditions without intervention.
  • Integrate with existing electrical power systems or microgrids and must enable coordinated operation with other energy sources and support performance under varying generation and load conditions.
  • Use a modular design that allows transport by air or ship — ensuring that individual components fit within a standard 20ft sea container with maximum dimensions of 108 in. (2.74 m) wide × 268 in. (6.81 m) long × 96 in. (2.44 m) high and a maximum weight of 24,000 lb (10,886 kg; 10.9 tonnes).
  • The modular design must enable onsite assembly without the need for heavy lift equipment.
  • Support maintainability and repairability in northern environments by ensuring the wind powered electric generator system can be serviced using standard mechanical and electrical tools, without reliance on specialized proprietary equipment or manufacturer field support.

Desired Outcomes

Proposed solutions should include capabilities such as, but not limited to, the following:

  • Electromagnetic interference that complies with MIL STD 461G, Department of Defense Interface Standard for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment.
  • Foundation design that accounts for Arctic ground conditions, including permafrost, active-layer variation, and freeze-thaw effects, over the intended design life of the generator.

Selection criteria

Highest Technical Merit within a Stipulated Maximum Budget

AI Summary

This Challenge notice is issued under the Innovation for Defence Excellence and Security (IDEaS) Program Call for Proposals (CFP) Call 006 (W7714-248676/A). Solicitation Documen...

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
cb-16-26836159
Solicitation no.
W7714-248676/016
Buyer
Department of Public Works and Government Services (PSPC)
Notice type
Request for Proposal
Method
Competitive - Open bidding
Procurement category
*SRV
Trade agreements
*Canadian Free Trade Agreement (CFTA)
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

UNSPSC
UNSPSC 26000000 — Power Generation and Distribution Machinery and Accessories

Delivery & regions

Province
Quebec
Regions of opportunity
*Canada
Regions of delivery
*Canada

Key dates

Published
September 10, 2026
Closes
October 20, 2026
Amendment no.
002
Amendment date
October 6, 2026

Contact

Contact
P•••• I•••• T••• / L••••••• I•••• d• T••••
Email
t••••••••@••••••••.••.ca
Address
••• •••••••• •• •••••••, ••••••••, ••••••, ••• •••, ••••••
Sign up free to see the contact details

Likely incumbents

(5)

Suppliers who have won similar work from this buyer before.

  1. 1
    Ador tech Inc.
    5 contracts won· latest January 8, 2026
    CAD $327.5K
    total awarded
  2. 2
    Toromont Cat (Québec)
    4 contracts won· latest October 30, 2023
    CAD $1.1M
    total awarded
  3. 3
    Flender Corporation Canada
    3 contracts won· latest January 30, 2026
    CAD $2.7M
    total awarded
  4. 4
    TOTAL POWER LIMITED
    3 contracts won· latest February 5, 2024
    CAD $1.2M
    total awarded
  5. 5
    Firstchoice Group Canada
    3 contracts won· latest September 17, 2026
    CAD $281.2K
    total awarded

Ador tech Inc. is the most likely incumbent, based on how often and how recently they have won this buyer’s work in this category. To displace them, expect to need a clearly stronger proposition or price.

Documents

(1)
Complete source record(32)
Title
Modular Wind Power for Northern Operations
Reference number
cb-16-26836159
Amendment number
002
Solicitation number
W7714-248676/016
Publication date
2026-09-10
Tender closing date
2026-10-20T14:00:00
Amendment date
2026-10-06
Tender status
Open
Unspsc
*26111607 *26131500 *39121500 *92111700
Unspsc description
*Solar generators *Power plants *Electrical controls and accessories *Military science and research
Procurement category
*SRV
Notice type
Request for Proposal
Procurement method
Competitive - Open bidding
Selection criteria
Highest Technical Merit within a Stipulated Maximum Budget
Trade agreements
*Canadian Free Trade Agreement (CFTA)
Regions of opportunity
*Canada
Regions of delivery
*Canada
Contracting entity name
Department of Public Works and Government Services (PSPC)
Contracting entity address line
200 Promenade du Portage
Contracting entity address city
Gatineau
Contracting entity address province
Quebec
Contracting entity address postal code
J8X 4B7
Contracting entity address country
Canada
Contact info name
P•••• I•••• T••• / L••••••• I•••• d• T••••
Contact info email
t••••••••@••••••••.••.ca
Contact info address line
••• •••••••• •• •••••••
Contact info city
••••••••
Contact info province
••••••
Contact info postalcode
••• •••
Contact info country
••••••
Attachment
https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/106085/cfp-6--ch16-%28w7714-248676-011-a-questions-and-answers---questions-et-reponses-%28w7714-248676-010-a-ap6-defi-16.pdf,https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/106085/ch16--modular-wind-power-for-north-operations--defi16--energie-eolienne-modulaire-pour-le-nord.pdf,https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/106085/w7714-248676-ideas-cfp-006---amendment-2.pdf,https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/106085/cfp-6--ch16-%28w7714-248676-011-a-questions-and-answers---questions-et-reponses-%28w7714-248676-010-a-ap6-defi-16.docx_.pdf
Tender description
This Challenge notice is issued under the Innovation for Defence Excellence and Security (IDEaS) Program Call for Proposals (CFP) Call 006 (W7714-248676/A). Solicitation Documents reference: See bidding details section. *For additional general information on the IDEaS Program, visit: https://www.canada.ca/en/department-national-defence/programs/defence-ideas.html _____________ This challenge is open to receive proposals for Component 1a, Component 1b and Component 2. Proposed solutions that fall within technology readiness levels (TRL) 1-9 can be submitted to this challenge. Steps to apply: Step 1: read this challenge Step 2: read the Call for Proposals : See bidding details section Step 3: propose your solution here : https://defence-innovation-portal.my.site.com/ _____________ Maximum Funding and Performance Period Multiple contracts could result from this Challenge. The individual maximum contract funding available under Component 1a (TRL 1-3) is up to $250,000 CAD (excluding applicable taxes) for a maximum performance period of up to 6 months. The maximum individual contract funding available under Component 1b (TRL 4-5) is up to $1,500,000 CAD (excluding applicable taxes) for a maximum performance period of 12 months. The maximum individual contract funding available under Component 2 (TRL 6-9) is up to $5,000,000 CAD (excluding applicable taxes). The period of performance will be determined at the time of contract negotiation. The maximum individual contractual funding and the maximum performance period offered under Component 3 will be determined by Canada at the time of contract negotiation. This disclosure is made in good faith and does not commit Canada to contract for the total approximate funding. _____________ Challenge Details Challenge Title: W7714-248676/016 - Modular Wind Power For North Operations The Department of National Defence and Canadian Armed Forces (DND/CAF) are seeking innovative solutions to develop modular, stand-alone wind-powered electric generator systems that can be easily transported, deployed, and maintained in remote northern locations to provide reliable, clean energy under extreme cold, high-wind, and icing conditions. Background & Context The demand for electrical power and space heating in the Canadian Subarctic and High Arctic is fulfilled almost exclusively with diesel-fired generators. The DND/CAF is seeking to reduce reliance on fossil fuels for the generation of electrical power in the North to minimize operational, logistical, and environmental burdens. Wind turbines suitable for DND/CAF operations are in limited use in the North, as existing installations tend to fall outside the desired capacity range. While small units that deliver up to 6 kilowatts (kW) have been deployed in some communities, and commercial turbines typically exceed 1 megawatt (MW), there is a critical gap in the 25–100 kW range—an ideal scale for remote DND sites. In addition, northern operating conditions present major technical and environmental hurdles that must be overcome before wind turbines can be fully exploited as a source of alternative energy. Canada's far North and Arctic regions are characterized by seasonally frozen ground, deep snow, rugged terrain, permafrost, and extreme temperatures that can reach –60 degrees Celsius (°C), with frequent high winds of 80–120 kilometers per hour (km/h). Ice rimming of wind turbine blades further threatens performance and efficiency. Innovative approaches are therefore needed to adapt conventional wind-powered electric generator designs to withstand these harsh northern conditions and operate effectively under both low and high wind scenarios. Climate change adds additional complexity, as thawing and refreezing permafrost can cause buildings and foundations to sink, shift, or crack. While not the primary focus of the challenge, consideration must be given to the design of the foundations to keep the turbines level and stable despite seasonal ground movement. There is a need for wind-powered electricity generators that are logistically efficient, easy to deploy, and maintainable in isolated northern locations. Many DND/CAF sites exist in remote areas or within small Arctic communities that have limited or no road access and must be reached by alternative means of transportation such as barges or heavy-lift aircraft. Consequently, new systems must feature modular designs that can be transported and assembled on site with minimal heavy-lift equipment by non-technicians using commonly available tools. To ensure sustained operation, proposed solutions should use readily available parts, be serviceable by local tradespeople, and operate with minimal human intervention once deployed. Essential Outcomes The proposed solution must: • Provide a design for a wind-powered electrical generation system in the 25–100 kW range, incorporating details of the structural, mechanical, electrical, and control elements required. • Provide integration and operational demonstration plan(s), showing how the wind-powered electric generator system can function in remote northern locations and operate and withstand northern environmental conditions, including extreme cold (down to –60 °C), high winds (up to 120 km/h), and icing conditions without intervention. • Integrate with existing electrical power systems or microgrids and must enable coordinated operation with other energy sources and support performance under varying generation and load conditions. • Use a modular design that allows transport by air or ship — ensuring that individual components fit within a standard 20ft sea container with maximum dimensions of 108 in. (2.74 m) wide × 268 in. (6.81 m) long × 96 in. (2.44 m) high and a maximum weight of 24,000 lb (10,886 kg; 10.9 tonnes). • The modular design must enable onsite assembly without the need for heavy lift equipment. • Support maintainability and repairability in northern environments by ensuring the wind powered electric generator system can be serviced using standard mechanical and electrical tools, without reliance on specialized proprietary equipment or manufacturer field support. Desired Outcomes Proposed solutions should include capabilities such as, but not limited to, the following: • Electromagnetic interference that complies with MIL STD 461G, Department of Defense Interface Standard for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment. • Foundation design that accounts for Arctic ground conditions, including permafrost, active-layer variation, and freeze-thaw effects, over the intended design life of the generator.

Live tenders

Department of National Defence (DND)5 days left

JTRS Ground Adaptor Kit

Goods
75 MATCHView →
Arrow Utilities6 days left

Arrow Utilities - Request for Proposal - 3825.01 Generator Supply Contract

76 MATCHView →
University of Calgary7 days left

University of Calgary - Request for Proposal - Mobile Containerized Solar Microgrid System

79 MATCHView →