Nature of Requirements:
Modification to Notice of Proposed Procurement No: 3
Extend the bid closing date from December 19, 2016 to December 22, 2016
Modification to Notice of Proposed Procurement No: 2
Solicitation amendment no: 2 provides Canada responses to Bidders questions.
Modification to Notice of Proposed Procurement No: 1
Solicitation amendment no:1: Questions from bidders and Canadaresponses- Revision to the Statement of requirement
The Department of Fisheries and Oceans- Canadian Coast Guard as a requirement tosupply and deliver a sewage plant in accordance with Annex A, Statement of Requirements and delivered to Sidney, British Columbia on or before September 1, 2017.
STATEMENT OF REQUIREMENTS
SCOPE:
To supply and deliver (1) sewage plant suitable to process all black and grey water for 48 to 60 people. To supply and deliver (1) vacuum system to be connected to the toilet system and handle all black water.
REGULATORY REQUIREMENTS:
Must meet Annex A.1, item No.A.1/2.6 and Annex Module Bin the Directive. Marpol 73/78 as amended, Annex IV Regulation 9, IMO Res. MPEC 227(64) with the exemption of Section 4.2.
The system must be approved by a class society and be supplied with a Type Examination Certificate provided by the class society.
Canada shipping Act 2001 and relating regulations for vessel equipment - machinery
The classification societies must be an ?approved classification societies ?per the Transport Canada Marine Safety Marine Machinery Regulations SOR/90-264
SHORT TECHNICAL DESCRIPTION
The certified flow rate is to be not less than 6000 liters /day with a peak capacity of not less than 6150 Liters/day (for a period not exceeding 5 days)
The deck space is limited and all components for the system must fit in afoot print
Length: 3000mm
Width: 2100mm
Height: 2000mm
Note: The orientation of the sewage plant is restricted by the space available and the unit must operate correctly with the long axis being fore and aft.
The power required is 460volts/ 3phases/ 60 Hz. Complete with supplied transformers suitable for the controls.
Additional technical requirements can be found in the solicitation Annex ?A? - Statement of Requirements