Tendarix.ca
BUSINESS NEWS
Storm Clouds Continue to Gather Over Canada’s Economy· EnergyNowA new chapter in Canada-India economic relations· Business Council of CanadaQ3-26 Canadian Business Outlook Survey: More firms plan cost pass-through· RBCStaying in Canada is a 'huge relief' for Alberta business leaders· CBCPosthaste: U.S. businesses feel fresh pain from trade war with Canada, says this hot take on the economy· Financial PostCanada–Latin America Trade and Investment: Emerging Opportunities in a Changing Global Economy· McMillan LLPWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaCanadian business confidence weakens after U.S. trade talks collapse, BoC says By Investing.com· Investing.com CanadaGlobal trade is changing how the Canadian economy works· Bank of CanadaCanada’s inflation data, business survey on tap ahead of BoC decision· RBCEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsEastern Canada business leaders call for 'single economy' between Atlantic provinces· CastanetAtlantic Economic Panel unveils blueprint for Atlantic Canada’s future· Canada.caRegina business leaders to hear outlook on Canada's economy· SaskToday.caNew research finds electrifying Canada could add $3 trillion to the economy· Canadian Chamber of Commerce
← All tenders
Canadian Space Agency (CSA)

OSIRIS-REx Lab Organic and Inorganic Analyses Monitoring

Advance Contract Award Notice (ACAN)
Estimated value
Not disclosed
Deadline
November 3, 2026
Published
October 19, 2026
Type
Services
Explore similarEngineering and Research and Technology Based ServicesQuebec

Full description

The Canadian Space Agency (CSA) is recognized worldwide for its support to the exploration of space. An example of this support is the CSA’s contribution of the OSIRIS-REx Laser Altimeter (OLA) instrument to the asteroid sample return mission OSIRIS-REx. OSIRIS-REx is a NASA-led mission that returned a sample from asteroid Bennu to Earth in September 2023.

In return for Canada’s contribution of OLA, Canada will receive 4% by mass of the returned sample, marking Canada’s first samples returned from another solar system body and the 5th country in the world to have samples collected in space.

The CSA is now expanding its laboratory capacity to prepare for the arrival of its portion of the OSIRIS-REx sample. Specifically, CSA seeks to monitor particulate and air contamination in its laboratories This analysis must be comparable to NASA and JAXA, who also monitor contamination in their curation facilities using VPD-ICP-MS and TD-GD-MS analysis of silicon wafers and absorbent tubes.

Accordingly, the Canadian Space Agency requires a specialized service for monitoring organic and inorganic contamination in laboratories and clean rooms for the curation of astromaterials.

The Work will involve the following:

1. Analysis of silicon wafers by vapour phase decomposition (VPD) inductively coupled plasma mass spectrometry (ICP-MS) for trace metals;
2. Analysis of silicon wafers by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS) for organic compounds; and
3. Determination of organic in air by TD-GC-MS;
The Contractor must ship a series of 200 mm diameter bare silicon wafers and the absorbent tube to the CSA. The CSA will leave the wafer and tubes in the environment for 24 hours, following the Contractor’s provided instructions. The CSA will then ship the analytical equipment to the Contractor for analysis by VPD-ICP-MS and TD-GD-MS. All sampling must be appropriate for monitoring contamination in a cleanroom environment of ISO 7 classification or cleaner. The trace metal analysis must include the following elements: Al, As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Fe, Ga, Ge, Hf, In, K, La, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr, Ta, Ti, W, V, Y, Zn, and Zr. For both the passive and active monitoring of organics, the concentrations of organic compounds for the prepared wafers and absorbent tubes must be analyzed by TD-GC-MS, in addition the wafers for organic must follow the SEMI MF 1982-1103 Method-B procedure.

A sampling blank or control (transport blank) must be provided with the sampling kits. The Contractor must include any accessories required for sampling, such as stands and tweezer for the wafers or pumps for the absorbent tubes. The cleanrooms have strict material requirements.

Wafers and sampling absorbent tubes must be shipped in a manner that minimizes contaminants during transport allowing analysis of contamination in an extremely clean environment.

Selection criteria

Not applicable

AI Summary

The Canadian Space Agency (CSA) is recognized worldwide for its support to the exploration of space. An example of this support is the CSA’s contribution of the OSIRIS-REx Laser Al...

Intended sole-source award

The buyer plans to award this contract to a named supplier without competition. If your business can do this work, send a statement of capabilities to the contracting authority before November 3, 2026. If it qualifies, the buyer must open a full competition.

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
cb-280-37424447
Solicitation no.
9F012-20250210
Buyer
Canadian Space Agency (CSA)
Notice type
Advance Contract Award Notice
Method
Advance contract award notice
Procurement category
*SRV
Trade agreements
*Canadian Free Trade Agreement (CFTA)
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

UNSPSC
UNSPSC 81000000 — Engineering and Research and Technology Based Services

Delivery & regions

Province
Quebec
Regions of opportunity
*Quebec (except NCR)
Regions of delivery
*Quebec (except NCR)
Contract term
November 30, 2026 → March 31, 2027

Key dates

Published
October 19, 2026
Closes
November 3, 2026
Amendment no.
000

Contact

Contact
K••••••• D•••
Email
k••••••••@•••••••.••.ca
Address
•••• ••••• •• ••••••••, ••••••••, ••••••, ••• •••, ••••••
Sign up free to see the contact details

Award history

0 past awards in this classification and 5 likely incumbents from this buyer. Pro shows who won and for how much.

Upgrade to Pro

Documents

(1)
Complete source record(33)
Title
OSIRIS-REx Lab Organic and Inorganic Analyses Monitoring
Reference number
cb-280-37424447
Amendment number
000
Solicitation number
9F012-20250210
Publication date
2026-10-19
Tender closing date
2026-11-03T15:00:00
Expected contract start date
2026-11-30
Expected contract end date
2027-03-31
Tender status
Open
Unspsc
*81141902
Unspsc description
*Application or technology research and development service
Procurement category
*SRV
Notice type
Advance Contract Award Notice
Procurement method
Advance contract award notice
Selection criteria
Not applicable
Trade agreements
*Canadian Free Trade Agreement (CFTA)
Regions of opportunity
*Quebec (except NCR)
Regions of delivery
*Quebec (except NCR)
Contracting entity name
Canadian Space Agency (CSA)
Contracting entity address line
6767 Route de l'Aéroport
Contracting entity address city
St-Hubert
Contracting entity address province
Quebec
Contracting entity address postal code
J3Y 8Y9
Contracting entity address country
Canada
Contact info name
K••••••• D•••
Contact info email
k••••••••@•••••••.••.ca
Contact info address line
•••• ••••• •• ••••••••
Contact info city
••••••••
Contact info province
••••••
Contact info postalcode
••• •••
Contact info country
••••••
Attachment
https://canadabuys.canada.ca/sites/default/files/webform/tender_notice/110286/9f012-20250210_acan_en_osiris-rex-lab-monitoring.pdf
Tender description
The Canadian Space Agency (CSA) is recognized worldwide for its support to the exploration of space. An example of this support is the CSA’s contribution of the OSIRIS-REx Laser Altimeter (OLA) instrument to the asteroid sample return mission OSIRIS-REx. OSIRIS-REx is a NASA-led mission that returned a sample from asteroid Bennu to Earth in September 2023. In return for Canada’s contribution of OLA, Canada will receive 4% by mass of the returned sample, marking Canada’s first samples returned from another solar system body and the 5th country in the world to have samples collected in space. The CSA is now expanding its laboratory capacity to prepare for the arrival of its portion of the OSIRIS-REx sample. Specifically, CSA seeks to monitor particulate and air contamination in its laboratories This analysis must be comparable to NASA and JAXA, who also monitor contamination in their curation facilities using VPD-ICP-MS and TD-GD-MS analysis of silicon wafers and absorbent tubes. Accordingly, the Canadian Space Agency requires a specialized service for monitoring organic and inorganic contamination in laboratories and clean rooms for the curation of astromaterials. The Work will involve the following: 1. Analysis of silicon wafers by vapour phase decomposition (VPD) inductively coupled plasma mass spectrometry (ICP-MS) for trace metals; 2. Analysis of silicon wafers by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS) for organic compounds; and 3. Determination of organic in air by TD-GC-MS; The Contractor must ship a series of 200 mm diameter bare silicon wafers and the absorbent tube to the CSA. The CSA will leave the wafer and tubes in the environment for 24 hours, following the Contractor’s provided instructions. The CSA will then ship the analytical equipment to the Contractor for analysis by VPD-ICP-MS and TD-GD-MS. All sampling must be appropriate for monitoring contamination in a cleanroom environment of ISO 7 classification or cleaner. The trace metal analysis must include the following elements: Al, As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Fe, Ga, Ge, Hf, In, K, La, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr, Ta, Ti, W, V, Y, Zn, and Zr. For both the passive and active monitoring of organics, the concentrations of organic compounds for the prepared wafers and absorbent tubes must be analyzed by TD-GC-MS, in addition the wafers for organic must follow the SEMI MF 1982-1103 Method-B procedure. A sampling blank or control (transport blank) must be provided with the sampling kits. The Contractor must include any accessories required for sampling, such as stands and tweezer for the wafers or pumps for the absorbent tubes. The cleanrooms have strict material requirements. Wafers and sampling absorbent tubes must be shipped in a manner that minimizes contaminants during transport allowing analysis of contamination in an extremely clean environment.

Live tenders

Smoky Lake CountyClosing today

Smoky Lake County - Request for Proposal - HWY 28/63 Regional Water Commission Pipeline Condition Assessment and Renewal Prioritization Study

80 MATCHView →
Department of Natural Resources (NRCan)Closing today

Notice of proposed procurement (NPP)

Services
78 MATCHView →
Department of Public Works and Government Services (PSPC)Closing today

EW038-270709 - Northern Innovation Centre Conceptual Design Study – RFP

Construction
77 MATCHView →