Tendarix.ca
BUSINESS NEWS
What Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaBalsillie to co-lead new task force to help businesses benefit from the digital economy· Financial PostGlobal trade is changing how the Canadian economy works· Bank of CanadaHoles In Value Chains Are Holding Back Five Sectors That Have The Potential To Reshape Canada’s Economy For The Better· Canadian Chamber of CommerceEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsRegina business leaders to hear outlook on Canada’s economy· 620 CKRMDeloitte Canada cuts GDP growth forecast by 20% as tariffs grip economy amid Trump's trade war· CBCPrime Minister Carney introduces new Productivity Mega Deduction to boost Canada’s advantage as the most competitive G7 country for new business investment· Prime Minister of CanadaDeloitte expects slowing pace of economic activity in Canada into 2027· Financial PostCanadian Business Leadership Takes Centre Stage in Calgary· Canadian Chamber of CommerceThe first Canada Investment Summit unleashes nearly $500 billion of new investment in Canada· Prime Minister of CanadaWhat would being an 'associate member' of the EU mean for the Canadian economy and businesses?· Financial PostBank of Canada rate hikes to be limited by soft economy, report says· The Globe and MailCanada’s Productivity Push: Could Ottawa’s New Investment Strategy Accelerate Economic Growth and Business Spending?· kalkine.caMark Carney pitches Canada to global investors amid US trade war· Al Jazeera
← All tenders
National Research Council of Canada

Remplacement de la tour de refroidissement de la soufflerie trisonique

Request for Proposal (RFP)
Estimated value
Not disclosed
Deadline
July 9, 2024
Published
June 7, 2024
Type
Construction
Explore similarBuilding and Construction Machinery and Accessories
Awarded
This contract has been awarded. Details are drawn from the federal award notice for this solicitation.
Winning supplier
Black & McDonald Limited
Contract value
CAD $2.3M
Award date
2024-08-20
Supplier location
Ottawa, On
Request for Proposal

Full description

Amendment 002

This amendment is being raised to: 1) Provide response to technical questions, 2) Provide 2 attachments: (MCC#4 (photos and photos figures 1-5), and 3) Addendum to Specification 23 05 15 - COMMON INSTALLATION REQUIREMENTS FOR HVAC PIPEWORK mentioned in the technical answer in Amendment No. 002.

--------------------------------------------------------

Amendment 001

This amendment is being raised to: 1) Provide an Extension of Time, 2) Provide response to technical questions, and 3) Provide attachment (photos figures 1-14) mentioned in the technical answer in Amendment No. 001. Please see the Attachments section.
----------------------------------------------------------

NOTICE OF PROPOSED PROCUREMENT (NPP)

PROJECT TITLE: Construction of Trisonic Wind Tunnel Cooling Tower Replacement

PROJECT IDENTIFICATION: 942543

PROJECT DESCRIPTION:
The National Research Council Canada (NRC) requires a General Contractor to carry out construction work to supply and install a new cooling tower system at NRC’s Trisonic Wind Tunnel Facility, located at Uplands Campus, Bldg. U-66, 655 Levy Private, in Ottawa, Ontario. The scope of work is to construct a new cooling tower outside of the north side of Building U66, located at 655 Levy Private, Ottawa, Ontario. The General Contractor will be required to procure equipment and material for the cooling tower on behalf of NRC and hire sub-contractors to construct and install the new equipment specified in the Issued for Tender design package.

Provide General Contractor construction services as outlined in the construction documents, including but not limited to:

  • Erecting and maintaining a secure construction area;
  • Procurement of equipment for the cooling system;
  • Constructing the cooling tower system;
  • Installing electrical upgrades and connections;
  • Installing new cooling piping and connecting to the existing system;
  • Commissioning of the cooling tower systems;
  • Proving training to facility staff;
  • Removing the existing interim cooling system and foundation;
  • Project reporting;
  • Preparing as-built drawings;
  • Participating in bi-weekly construction meetings.

PROJECT BACKGROUND:
Building U-66 houses the 1.5 m Trisonic Wind Tunnel used by Aerospace Research Centre to conduct research in design, manufacturing, performance and maintenance of air and space vehicles. The 1.5 m Trisonic Wind Tunnel is a pressurized, intermittent-flow wind tunnel capable of providing subsonic, transonic and supersonic flows,

A cooling tower, originally built in 1959, provides essential cooling water to various parts of the compressor plant. A severe storm on May 21, 2022, damaged the tower beyond repair. A temporary steel piping spray system was installed; however, it lacks sufficient capacity to accommodate the cooling loads for current and future needs.

OPTIONAL SITE VISIT
1. There will be a site visit on June 19, 2024 at 10:00AM EDT. Interested bidders are to meet at the National Research Council Canada, Cooling Tower on the north side of Building U66, located at 655 Levy Private, Ottawa, Ontario.
2. Safety Attire: In order to be guaranteed access to the site visit all persons should have the proper personal protection equipment (safety glasses, footwear, vests and hard hats etc.). Contractor`s personnel/individuals who do not have the proper safety attire may be denied access to the site.

CONSTRAINTS
There will be client testing in the wind tunnel facility from September 01, 2024 to March 31, 2025. During this time, shutdowns to the existing cooling system will not be permitted during working hours. Short shutdowns during non-working hours may be permitted with prior approval from the research facility. A formal request must be submitted to the project manager at least two weeks in advance of any planned shutdown.

CONSTRUCTION TIME
The Contractor must perform and complete the Work within (42) forty-two weeks

THIS SOLICITATION CONTAINS AN INDIGENOUS PARTICIPATION PLAN
As part of the Reconciliation initiative Canada has included an Indigenous Participation Plan in this Tender therefore the bidders can include an (IPP) as part of their proposal. The IPP must demonstrate that, in carrying out the work outlined in the request for proposal, the bidders will use economic measures such as employing Indigenous labour, engaging Indigenous professional services or hiring Indigenous firms. Please see SI 22 for details.

SECURITY REQURIEMENTS
This procurement contains a mandatory security requirement. Before award of a contract, the Bidder must hold a valid Security Clearance as indicated in section SC01 of the Supplementary Conditions. Failure to comply with this requirement will render the Bid non-compliant and no further consideration will be given to the Bid.

EVALUATION AND SELECTION:
The Contractor Selection Methodology will be highest combined rating of technical merit and price.
The bidder must achieve a pass mark of 24 out of 40 (60%) to obtain an overall score. The successful Bidder shall be the one who accumulates the highest Combined score of the Technical weighted score (40%) and Tendered amount score (60%)

Bid proposals will be evaluated in accordance with a combination of mandatory and point rated criteria
M1. Bidder Experience on Similar Project
M2. Key Personnel – Construction Site Supervisor
M3. Key Personnel – Construction Project Manager
R1. Experience of Bidders on Similar Projects
R2. Bidder’s Key Project Personnel
R3. Management of Asbestos Abatement Projects
R4. Project Schedule
R5. Indigenous Participation Plan

TENDER DOCUMENTS
Firms intending to submit tenders on this project should obtain tender documents through the Canadabuys. Drawings and specifications are now published and available free of charge in PDF format only. Bidders should take note that attachments contain the full set of drawings and specifications, which consist of PDF files organized in an industry-standard directory structure. Addenda, when issued, will be available from Canadabuys. Firms that elect to base their bids on tender documents obtained from other sources do so at their own risk and will be solely responsible to inform the tender calling authority of their intention to bid.

ISSUED FOR TENDER DOCUMENTS:
1. Mechanical Drawings 6217-M01 to 6217-M07;
2. Electrical Drawings 6217-E1 to 6217-E5;
3. Structural Drawings 6217-S1 to 6217-S3;
4. Specifications;
5. Project-Specific Designated Substances and Hazardous Materials Survey.

ENQUIRIES
All enquiries of a technical and contractual nature are to be submitted to the Contracting Officer at E-mail: C••••••••@••••••••.••.ca.
Enquiries are to be made in writing and should be received no less than five (5) business days prior to the closing date to allow sufficient time to respond.

For more information, resources, technical support, or to register for a Business Number, please visit Canadabuys Service Desk at https://canadabuys.canada.ca/en/support.

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
cb-191-94689754
Solicitation no.
24-58036/A
Buyer
National Research Council of Canada
Notice type
Request for Proposal
Method
Competitive - Open bidding
Procurement category
*CNST
Trade agreements
*Canadian Free Trade Agreement (CFTA)
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

UNSPSC
UNSPSC 22000000 — Building and Construction Machinery and Accessories

Delivery & regions

Regions of delivery
*National Capital Region (NCR) *Canada

Key dates

Published
June 7, 2024
Closes
July 9, 2024
Amendment no.
004

Live tenders

University of Alberta1 day left

University of Alberta - Request for Proposal - Ice-Resurfacer

79 MATCHView →
Rocky View County1 day left

Rocky View County - Invitation to Bid - ITT 26-009 2026 RR33 Regional Pathway

79 MATCHView →
City of Calgary1 day left

City of Calgary - Request for Proposal - Yorkville Temporary and Permanent Fire Station

78 MATCHView →