Trade Agreement: NAFTA/AIT/Canada FTAs with Peru/Colombia/Panama
Tendering Procedures: Generally only one firm has been invited to bid
Non-Competitive Procurement Strategy: Interchangeable Parts
Comprehensive Land Claim Agreement: No
Vendor Name and Address:
1737868 Ontario Inc.
200 Terence Matthews Cres
Kanata Ontario
Canada
K2M2C6
Nature of Requirements:
MULTIGAS 2030 FTIR ANALYZER
23375-160412/A
Gauthier, Martin
Telephone No. (613) 404-8642
Fax No. (819) 956-3814
1. Advance Contract Award Notice (ACAN)
An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or co
nstruction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a
statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then p
roceed with the award to the pre-identified supplier.
2. Definition of the requirement
The Natural Resource Canada has a requirement for (1) MultiGas 2030
FTIR Analyzer including installation, manuals in English and training for up to (2) users. The delivery is required by December 29, 2015 to Ottawa, Ontario.
3. Criteria for assessment of the Statement of Capabilities
Any interested supplier must demonstrate by way of a statement of capabilities that its product/equipment/system meets the following requirement:
The MKS 2030 FT-IR is the only system that has a 200 ml cell volume wi
th high detector sensitivity capable of analyzing gaseous components in
the range of ppb to 100% in the presence of 10-20% water vapour. To achieve this type of analysis in the presence of water, the MKS 2030 has an IR cell that can be heated to 191°C. This elevated temperature is a
regulatory requirement for diesel exhaust emission testing and is therefore needed to validate our results. The small cell volume co
mbined with the high detector sensitivity of the MKS is required due to
the small flow volume that is used during the testing of our catalysts.
Larger cell volumes, available from other manufacturers, would take
more time to fill and would result in loss of information about
chemical processes/reactions occurring during the experiment. The ppb sensitivity is needed to analyze level of gaseous concentrations that are typically present in the exhaust gases during the tests. The MKS can
analyze sample flows rates from 0.2-10 L/min. This range of flow rates is essential to achieve the gas hourly space velocities (GHSV) required f
or our catalyst evaluation. The MKS system has permanent calibration which means the instrument does not have to be calibrated on a regular basis. Instrument calibrations are time consuming and require expensive high
purity calibration gases. Thus the permanent calibration feature
allows for catalyst formulations to be optimized in a shorter time. CCR
Products is the only supplier that offers local support which is an
important and sometimescritical consideration in minimizing down time.
In summary, we have identified a combination of unique capabilities of the MKS 2030 gas analyzer that are critical for our application:
- ppb sensitivity in high water vapour concentration (10-20%)
- Celltemperature: 191°C
- Small volume cell size (200mL)
- Flow rate 0.2-10L/min
- Permanent calibration
- Local support
4. Applicability of the trade agreement(s) to the procurement
This procurement is subject to the following trade agreement(s):
Agreement on Internal Trade (AIT)
North American Free Trade Agreement (NAFTA)
5. Justification for the Pre-Identified Supplier
The only known supplier of Multigas 2030 FTIR Analyzer meeting all the above required technical specifications is CCR Process Products. For this reason, it is proposed to negotiate this requirement with CCR Process Products.
6. Exclusions and/or Limited Tendering Reasons
The following exclusion(s) and/or limited tendering reasons are invoked un
der the:
Agreement on Internal Trade (AIT) - Article 506.12(b)
North American Free Trade Agreement (NAFTA) - Article 1016.2(b)
7. Period of the proposed contract or delivery date
The final delivery of the equipment must be on December 29th, 2015.
8. Name and address of the pre-identified supplier
CCR Process Products
200 Terence Matthews Crescent
Kanata, Ontario
K2M 2C6
Canada
9. Suppliers' right to submit a statement of capabilities
Suppliers who consider themselves fully qualified and available to provide the goods, services or construction services described in the ACAN may submit a statement of capabilities in writing to the contact person identified in this notice on or before the closing date of this notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
10. Closing date for a submission of a statement of capabilities
The closing date and time for accepting statements of capabilities is December 2, 2015 at 2:00 p.m. EST.
11. Inquiries and submission of statements of capabilities
Inquiries and statements of capabilities are to be directed to:
Martin Gauthier
Supply Officer
Public Works and Government Services Canada
Scientific, Medical and Photographic Division - PV
Portage III - Floor: 6A2 - Room: 48
11 Laurier Street
Gatineau, Quebec
Canada
K1A 0S5
Telephone: 613-404-8642
Facsimile: 819-956-3814
E-mail: m••••••••@•••••.••.ca
Delivery Date: Above-mentioned
You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.
An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.
Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.