Trade Agreement: WTO-AGP/NAFTA/AIT/Canada FTAs with
Peru/Colombia/Panama
Tendering Procedures: All interested suppliers may submit a bid
Attachment: YES (MERX) Electronic
Competitive Procurement Strategy: Lowest/Lower Bid
Comprehensive Land Claim Agreement: No
Nature of Requirements:
INSERT Part 2 - 5. Mandatory Site Visit
It is mandatory that the Bidder or a representative of the
Bidder visit the work site. Arrangements have been made for site
visit to be held on 13 August, 2013 at 9:30a.m. at the Fort
Frances Point of Entry, 101 Church St., Fort Frances Ontario,
P9A 3X8. Bidders must communicate with the Contracting Authority
no later than 5 days before the scheduled visit to confirm
attendance and provide the names of the person(s) who will
attend. Bidders will be required to sign an attendance form.
Bidders should confirm in their bids that they have attended the
site visit. Bidders who do not attend or send a representative
will not be given an alternative appointment and their bids will
be rejected as non-compliant. Any clarifications or changes to
the bid solicitation resulting from the site visit will be
included as an amendment to the bid solicitation.
_________________________________________________________________
_____________
Security Access System
47504-131946/A
Kelly, Peter
Telephone No. - (819) 956-3992
Line1, Security Access System
Supplier to provide and install the following:
One (1) "non-proprietary-rights" security system that can manage
the security alarm, duress alarm and access control system
with lock-down capability.
One (1) computer to run system similar to: Dell Vostro 460
Desktop (Intel Core i7 (2600), Window 7, 8 GB RAM, on-board
graphic card, 1TB SATA hard drive, 16x DVD +/-RW) (able to run
all of the system's software requirements)
One (1) Uninterrupted Power Supply (UPS) that will provide one
hour of computer back-up power and surge protection;
One (1) 20 inch LCD or LED colour monitor.
Includes wiring, connectors, labour and shop supplies; re-use of
existing wiring, door contacts, motion detectors, duress alarm
buttons, siren/bells, etc. as cost effective.
Traffic Building - 1st floor
a. Seven (7) card readers
b. Two (2) keypad readers
c. Nine (9) door strikes
d. Eight (8) door contacts*
e. Eight (8) duress alarm buttons *
f. Eight (8) motion detectors *
g. One (1) alarm keypad
h. Three (3) bells/buzzers/sirens*
i. Two (2) alarm annunciators
j. Two (2) lock-down switches
k. Wiring, Connectors, Labour and Shop Supplies
*Existing wiring, door contacts, motion detectors, duress alarm
buttons, siren/bells, etc.. are to be re-used where cost
effective.
4.7 2nd floor
a. Six (6) card readers
b. Six (6) door strikes
c. Two (2) door contacts*
d. Two (2) duress alarm buttons*
e. Seven (7) motion detectors*
f. Two (2) Alarm keypads
g. Three (3) bells/buzzers/sirens*
h. Wiring, Connectors, Labour and Shop Supplies
i. One (1) computer as described above
*Existing wiring, door contacts, motion detectors, duress alarm
buttons, siren/bells, etc.. are to be re-used where cost
effective.
4.8 Warehouse
a. Four (4) card readers
b. Four (4) door strikes
c. Five (5) door contacts*
d. Four (4) motion detectors*
e. Three (3) alarm keypads
f. Three (3) bells/buzzers/sirens*
*Existing wiring, door contacts, motion detectors, duress alarm
buttons, siren/bells, etc.. are to be re-used where cost
effective.
4.9 Tertiary Garage
a. Two (2) card readers
b. Two (2) door strikes
c. Four (4) door contacts*
d. One (1) duress alarm button*
e. Two (2) motion detectors*
f. One (1) bell/buzzer/siren*
g. Two (2) alarm keypads
*Existing wiring, door contacts, motion detectors, duress alarm
buttons, siren/bells, etc.. are to be re-used where cost
effective.
The access control portion of the system must include lock-down
capabilities with two lock-down buttons.
Delivery Date: Above-mentioned
The Crown retains the right to negotiate with suppliers on any
procurement.
Documents may be submitted in either official language of Canada.