Nature of Requirements:
LOW LEVEL O2 & THC ANALYZERS
1. Advance Contract Award Notice (ACAN)
An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.
2. Definition of the requirement
The Natural Ressources Canada has a requirement for (1) Low Level 02 & THC Analyzers including installation, manuals and training for up to (2) users. The delivery is required by March 31, 2016 to Ottawa, Ontario.
3. Criteria for assessment of the Statement of Capabilities
Any interested supplier must demonstrate by way of a statement of capabilities that its product/equipment/system meets the following requirement:
CanmetENERGY Gasification Group Gas Analysis Requirements
Clean Fossil Fuels (CFF) is involved in the research and development of clean energy technologies and energy efficient combustion processes. The Group's research focuses on optimizing the performance of stationary equipment and evaluating and developing new products, fuels and retrofit technologies. Processes under study use conventional fuels such as: oil, coal and natural gas, as well as biomass and specialty fuels. This requires the monitoring of flue gas composition and combustion products.
CFF’s Combustion group has an immediate requirement for 1 O2 gas analyzer and 1 THC gas analyzer for continuous emission monitoring of the Aerojet Rocketdyne Oxy-PFBC Lab in the CanmetENERGY Bell=s Corners facility.
1. To ensure accuracy in measurements, the Gas Analyzers must meet or exceed the performance specifications as listed below.
2. Be able to measure real-time gas levels for O2 and CH4 within the gas composition listed:
Gas Composition
mol% mol% (dry)
CO2 98.419 99.2201
H2O 1.1575 0
AR 0.153 0.1548
N2 0.2153 0.1381
O2 NIL NIL
NO 0.0005 0.0005
NO2 0.0037 0.0037
SO2 0.0009 0.0091
SO3 0 0
CH4 0.05 0.0184
Specifications
Gas: O2 - 0 - 300ppm
Accuracy @ 20ºC: ± 2 ppm or ± 5% of measured value whichever is greater;
Operating environment:
Class I, Division II, Groups A, B, C, and D
Maximum Sample Temperature: 90°C non-continuous;
Limit of Detection (LOD): 0.5 ppm O2;
Response time: