Nature of Requirements:
REQUIREMENT
1.1 Mission Statement:
DFO buys, manages and operates numerous small craft in support
of its Departmental programs and other missions. The requirement
is for two 5.99 meter Aluminum Jet Boats; hull lengths must not
be exceeded. The vessel will be deployed in Owikeno and Long
lake to support Sockeye stock assessment programs in those areas
in support of the River and Smith Inlet Ecosystem recovery plan.
1.2 Utilization:
These boats will be used for riverine and lake salmonid stock
assessment field programs in Owikeno and Long Lake. This
involves operations in the large lakes which often have wind
driven waves and various river conditions and extensive work in
shallow braided channels and fast flowing rapids of the
tributary streams. The boats are required to be capable of
operating in up to class III Swiftwater (International River
Rating) and in shallows (i.e. 6 inches and less). They will also
serve as camp tenders and boom boats for pushing logs and debris
out of the fish fence location at Long Lake and servicing the
shear booms and floating camp structures at Owikeno Lake.
DELIVERY
Delivery of these vessels, to their various destinations, must
be completed by the MANDATORY delivery date of 12 Ocober 2012.
PHYSICAL CHARACTERISTICS OF THE VESSEL
1. Length (hull) must be approx. 5.99m
2. Normal load conditions
a) Crew of 5
b) Fuel 250 litres in one tank
c) Equipment and supplies 200 kg
REQUIRED OPERATIONAL PERFORMANCE
1. Unless otherwise stated, performance must be for conditions
of zero sea state and no wind, in fresh water with Normal Load
and complement. The craft must be designed and constructed for
ease of maintenance and repair, long life, and to be easily
supportable by local commercial facilities and suppliers. The
craft is expected to have a service life of at least 10 years,
with an expected usage of between 200 and 300 hours per year.
2. Maximum desired speed of 35 to 38 knots in Normal Load
condition.
MANDATORY CONSTRUCTION STANDARDS
1. Transport Canada Marine Safety Regulation TP 1332
"Construction Standards for Small Vessels", which incorporate
references to ABYC standards for equipment such as fuel tanks
and fuel systems, as well as tank space ventilation, and ISO
standards for stability, loading capacity, etc. as delegated to
ISO 12217-1.
Http://www.tc.gc.ca/MarineSafety/Directorate/TP/tp1332/tp1332e.ht
m
2. Canadian Standards Association C22.2 NO. 183.2-M1983 (R1999)
"Standards for D.C. Electrical Installations on Boats and ABYC
'E' electrical standards."
INSPECTION/QUALITY ASSURANCE/QUALITY CONTROL
1. The Contractor must prepare an Inspection and Test Plan (ITP)
for this project.
2. The Contractor must conduct inspections in accordance with
the ITP.
3. The Contractor on the inspection record, test or trials
sheets as applicable must record the results of each inspection.
The Contractor must maintain files of completed inspection
records.
The entire Inspection process is outlined in Annex D of the
Request for Proposal.
TRADE AGREEMENTS
This Purchase is being made under GSIN N1940G, and therefore
subject to the Agreement on Internal Trade and the North
American Free Trade Agreement (NAFTA).
Delivery Date: Above-mentioned
The Crown retains the right to negotiate with suppliers on any
procurement.
Documents may be submitted in either official language of Canada.