Public Works and Government Services Canada (PWGSC) is asking interested parties to provide information for a potential lease of space that meets the following criteria:
Section A: Lease Components
a lease term of approximately four (4) years, commencing on or about May 1st, 2019, plus one (1) option to extend the lease for an additional period of one (1) year;
approximately 183 usable square metres (um2) of contiguous warehouse space and four (4) parking spaces;
the proposed space must be available approximately two (2) weeks prior to the above-noted lease commencement date so all space may be prepared for occupancy;
the proposed space should satisfy or be capable of satisfying the following criteria:
the warehouse portion of the leased premises shall have:
a minimum unobstructed warehouse ceiling height of 3.05 metres (10’) throughout measured from the top of the finished floor to the underside of the lowest obstruction of the ceiling, including HVAC, electrical, and sprinkler system;
a minimum of one (1) overhead doors with grade access having a minimum door size of 2.13 m high x 2.74 m wide (7’ x 9’);
a minimum floor loading capacity of 4.8 kPa through-out (100 psf);
a man door for pedestrian access.
must have a floor drain;
the building/property must have public parking;
the proposed space must have all basic utilities, including telecommunications, water, sewer, gas and electricity;
a public transit stop must be within 500 metres of the building main entrance, and the frequency of service must not be greater than 30 minute intervals between the hours of 0700 hours and 1800 hours, Monday to Friday inclusive; there must be an accessible walking route between the public transit stop and the building;
the physical characteristics of the lands and the building and the area and environment surrounding it, including neighbouring land uses, shall be compatible with the Lessee’s intended use of the accommodation.
the proposed space must be located in the city of Edmonton and within the following boundaries (the geographical boundaries include sites on either side of the roads):
North: East on 111th Avenue /112th Avenue to Anthony Henday Drive
South: 41st Avenue SW
East: South on Anthony Henday Drive / 17th Street SW to 41st Avenue SW
West: North on 184th Street SW / Anthony Henday Drive
on or before the lease commencement date, the proposed space will have to comply with all requirements contained in PWGSC’s Standards for Leased Accommodation, a copy of which may be obtained from the contact listed in Section F;
Note: PWGSC may wish to visit or inspect the proposed space upon reasonable notice and a threat and risk assessment may be undertaken in order to assess potential threats to the security of the proposed space and to the public.