Storm Clouds Continue to Gather Over Canada’s Economy· EnergyNowOpinion: Mark Carney’s climate ambitions still threaten Canada’s economy· Financial PostQ3-26 Canadian Business Outlook Survey: More firms plan cost pass-through· RBCA new chapter in Canada-India economic relations· Business Council of CanadaStaying in Canada is a 'huge relief' for Alberta business leaders· CBCTrump administration cancels some Canada tariffs amid close midterm races· NBC NewsWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaCarney, Erdogan launch ‘strong and resilient’ Canada-Turkiye partnership· Al JazeeraJapan-Canada Chambers Council Joint Statement· Canadian Chamber of CommerceGlobal trade is changing how the Canadian economy works· Bank of CanadaEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsSoft economy should limit Bank of Canada's rate hikes: Capital Economics· BNN BloombergCanada’s services PMI shows sector shrinking for fourth straight month in September· The Globe and MailCanada’s inflation data, business survey on tap ahead of BoC decision· RBCPosthaste: U.S. businesses feel fresh pain from trade war with Canada, says this hot take on the economy· Financial Post
← All tenders
Canadian Nuclear Safety Commission

Orientation en matière de réglementation sur les générateurs de vapeur de remplacement – Étude expérimentale sur l’incidence des supports de méplats sur l’instabilité fluide élastique parallèle à l’écoulement des générateurs de vapeur (R682.1)

Request for Proposal (RFP)
Estimated value
Not disclosed
Deadline
August 14, 2017
Published
July 3, 2017
Type
Services
Explore similarOntario

Full description

1.0 Background
Flow-induced vibrations of tubes in steam generator U-bends can lead to a loss of tube integrity due to fretting wear at the tube supports and/or from tube-to-tube impacting. Since these tubes represent the pressure boundary between the irradiated primary side coolant and the secondary side flows, their failure constitutes a breach of containment, and therefore such tube leaks cannot be tolerated. Until the recent operating experience of steam generator tube degradation at San Onofre Nuclear Power Plant, streamwise (or more frequently referred to as in-plane) fluid-elastic instability (FEI) was considered not to be a problem. Indeed, the ASME and JSME Codes do not require consideration of streamwise FEI. While design guidelines against such damaging vibrations are in place, tubes failures still occur and the danger increases as the time in service of steam generators grows longer, and when replacement steam generators do not precisely replicate the original designs.
The steam generator (SG) design guidelines are based largely on empirical data from laboratory experiments and design code verification is strongly dependent on service experience. Thus, when new or replacement steam generators (RSGs) are designed, any departure in design from previously proven hardware creates risk. The best proof of this is the permanent shutdown of the San Onofre Nuclear Generating Station (SONGS) in 2012 after operating brand new replacement steam generators for only two years. In fact, one of the units developed large numbers of tube failures after only 11 months of service. These new SGs replaced the original steam generators which had given about 25 years of service. The failures were due to tube-to-tube impacting from in-plane fluid-elastic instability in the U-bends, something which had never before been seen in steam generators in service. Indeed, the current practice was to ignore this as a possible failure mode. The failure of RSGs resulted in a disaster for the nuclear industry and, numerous critiques from the Office of Inspector General pointed to US Nuclear Regulatory Commission (US NRC). Neither Southern California Edison, as the plant operator, nor the US NRC, as the national regulator, saw the risk associated with the RSG design and operation. It is clear that the current design guidelines are inadequate to deal with advanced designs which specify hardware which is beyond our operating experience. Independent research study is required to address needs of a national regulator and to improve our understanding of the effects of such parameters as tube pattern and pitch ratio, tube-to-support clearances and void fraction on tube response to flow-induced vibrations.

2.0 Objectives
CANDU utilities are in process of replacing aging steam generators (48 replacement steam generators to be design, manufactured and installed by 2028. The replacement steam generators differ from the original steam generators already licensed. The purpose of this project is to develop this required knowledge and to provide essential information for ensuring that the CNSC staff can make informed assessments of vendor’s designs. The key deliverable of the research project is a guide for a regulatory assessment of the design and operation of replacement steam generators for CANDU reactors.
3.0 Scope of Work
The proponent must develop modelling and complete an experimental laboratory study of flow-induced vibrations of tubes in a scaled sectional model of a CANDU type nuclear steam generator under conditions in which the current understanding and available data for design and evaluation is inadequate. Steam-water or a suitable refrigerant must be used to achieve two-phase flow conditions rather than an air-water mixture. Particular attention should be paid to consider the situations of high void fractions (around 90%) in which service failures generally occur. Tube failures in steam generator service may occur in the regions of the U-bends where the void fraction is highest and therefore, the velocities are the highest and the tube damping is least. It is these areas which have not been studied adequately, especially with regard to stream-wise fluid-elastic instability. Extensive measurements must be performed to determine tube response, stability and damping as a function of mass flux and void fraction. Experiments must be carried out to study the effect of flat bar supports on both transverse and streamwise stability of the tubes, including the effects of tube-to-support clearance.
CNSC staff are aware that such experiments conducted in two phase flows at very high void fractions could be challenging.
4.0 Tasks to be Performed

 Literature survey and review of existing knowledge in the area of stream-wise vibrations in steam generators and heat exchangers.
 Review operating experience with replacement steam generators already in operation along with design changes made with RSG vs original SG design.
 Identify critical flow and structural parameters of importance for initiation and propagation of streamwise vibrations
 Identify most vulnerable array geometry for initiation of streamwise vibrations and critical parameters (tube pitch, array geometry, circulation ratio, tube support clearances, void fraction, …)
 Develop structural scaling from CANDU steam generator to experimental test bundle
 Propose preliminary design for experimental setup

 Develop instrumentation to measure critical parameters, tube frequency response, damping ratio, tube rms amplitude response, and thermal hydraulics parameters
4.8 Define experimental test matrices
4.9 Propose model for streamwise flow induced vibration
4.10 Perform benchmark experiments with data for tube response, stability threshold and damping for a range of void fraction from 60% to about 95%

Analyse experimental results and model predictions to validate model.
Re-evaluate test plan if necessary. Perform experiments to study effects of flat bar supports on stability. Quantify the effect of flat bar supports with specified clearance
Perform set of experiments on the effect of clearance on stability

Prepare report with complete experimental results, analysis, and implications for steam generator design. Develop guidelines for regulatory assessment of design and performance of replacement steam generators.

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
PW-17-00785166
Solicitation no.
87055-17-0055
Buyer
Canadian Nuclear Safety Commission
Notice type
Request for Proposal
Method
Competitive - Open bidding
Procurement category
*SRV
Trade agreements
*Agreement on Internal Trade (AIT) *North American Free Trade Agreement (NAFTA)
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

GSIN
*B304A — *Regulatory Studies

Delivery & regions

Province
Ontario
Regions of delivery
*National Capital Region (NCR)

Key dates

Published
July 3, 2017
Closes
August 14, 2017
Amendment no.
000

Contact

End-user
Canadian Nuclear Safety Commission
Sign up free to see the contact details

Live tenders

Royal Canadian Navy (RCN)Closing today

Furniture Installation

Indigenous set-asideGoods
75 MATCHView →
Department of National Defence (DND)1 day left

4 X Winter Loaders Rental

Services
78 MATCHView →
Department of Public Works and Government Services (PSPC)1 day left

Solicitation of Offers – FR-EN Translation Services - General and Administrative Texts Field- Tier 2

Services
79 MATCHView →