Storm Clouds Continue to Gather Over Canada’s Economy· EnergyNowOpinion: Mark Carney’s climate ambitions still threaten Canada’s economy· Financial PostQ3-26 Canadian Business Outlook Survey: More firms plan cost pass-through· RBCA new chapter in Canada-India economic relations· Business Council of CanadaStaying in Canada is a 'huge relief' for Alberta business leaders· CBCTrump administration cancels some Canada tariffs amid close midterm races· NBC NewsWhat Canadian Businesses Must Embrace to Compete in a Volatile Global Economy· Open CanadaCarney, Erdogan launch ‘strong and resilient’ Canada-Turkiye partnership· Al JazeeraJapan-Canada Chambers Council Joint Statement· Canadian Chamber of CommerceGlobal trade is changing how the Canadian economy works· Bank of CanadaEastern Canada business leaders call for ‘single economy’ between Atlantic provinces· Global NewsSoft economy should limit Bank of Canada's rate hikes: Capital Economics· BNN BloombergCanada’s services PMI shows sector shrinking for fourth straight month in September· The Globe and MailCanada’s inflation data, business survey on tap ahead of BoC decision· RBCPosthaste: U.S. businesses feel fresh pain from trade war with Canada, says this hot take on the economy· Financial Post
← All tenders
Canadian Nuclear Safety Commission

Projet de recherche 557.1 - Application du critère de défaillance unique pour la CCSN

Request for Proposal (RFP)
Estimated value
Not disclosed
Deadline
September 9, 2013
Published
August 1, 2013
Type
Services
Explore similarOntario

Full description

The safety analysis of a nuclear power reactor is a complex undertaking. Within this analysis, a criterion (or requirement) is applied to a safety system such that the system must be capable of performing its task in the presence of any single failure; this requirement is commonly referred to as the Single Failure Criterion (SFC).

The capability of a system to perform its design function in the presence of a single failure could be threatened by a common cause failure such as a fire, flood, or human intervention. In a postulated design basis initiating event, the SFC requires that each safety system performs all safety functions as designed, and mitigates:
1. All failures caused by that single failure;
2. All identifiable but non-detectable failures, including those in the non-tested components; and
3. All failures and spurious system actions that cause (or are caused by) the postulated event.
Requirements for SFC are currently addressed in CNSC regulatory documents RD-337, Design of New Nuclear Power Plants, and RD-367, Design of Small Reactor Facilities.

The objective of this project is to recommend regulatory design requirements for new reactors that shall address Single Failure Criterion best-practice, particularly as it relates to in-service testing, maintenance, repair, inspection and monitoring of Systems, Structures and Components important to safety.

AI Analysis

Get a plain-English breakdown of this tender — what they need, who can bid, how to approach it, and tips for small suppliers. Takes a couple of seconds.

Basic information

Reference
PW-13-00359384
Solicitation no.
87055-13-0159 (R557.1)
Buyer
Canadian Nuclear Safety Commission
Notice type
Request for Proposal
Procurement category
*SRV
Trade agreements
*None
Estimated value
Not disclosed
Source
canadabuys

Classification & terms

GSIN
*S-R0 — *Professional Services

Delivery & regions

Province
Ontario
Regions of delivery
*National Capital Region (NCR)

Key dates

Published
August 1, 2013
Closes
September 9, 2013
Amendment no.
000

Contact

End-user
Canadian Nuclear Safety Commission
Sign up free to see the contact details

Live tenders

Royal Canadian Navy (RCN)Closing today

Furniture Installation

Indigenous set-asideGoods
75 MATCHView →
Department of National Defence (DND)1 day left

4 X Winter Loaders Rental

Services
78 MATCHView →
Department of Public Works and Government Services (PSPC)2 days left

Solicitation of Offers – FR-EN Translation Services - General and Administrative Texts Field- Tier 2

Services
79 MATCHView →